Eastman chemical

Organization
Eastman Chemical Company
P.O. Box 7444
Longview, TX  75607
Equipment

Two isolation control valve systems in a high-pressure polyethylene plant

Objective

To improve valve reliability by the reduction of contamination and silting problems.  Kidney loop filtration was added to the system resevoirs.  Halex Coils were used with the spin-on filters in the kidney loop systems.

Results

ISO cleanliness codes improved from 21/18 to 11/8 and from 18/11 to 12/8 in the two systems.  Since the installation of the filtration system, no valves have stuck, but have responded as needed.

Scan of the lab results and correspondence with Eastman (1.10 MB PDF file)

System 1
Sample 0829 was taken upstream before the installation of Halex Coils.
Sample 0830 was taken downstream before the installation of Halex Coils.
Sample 0911 was taken upstream after the installation of Halex Coils.
Sample 0912 was taken downstream after the installation of Halex Coils.
Spectrographic analysis (ppm)
Sample
received
Fe
Iron
Cr
Chromium
Mo
Molybdenum
Al
Aluminum
Cu
Copper
Pb
Lead
Sn
Tin
Ag
Silver
Ni
Nickel
Sb
Antimony
0829 1 0 0 0 0 0 0 0 1 0
0830 1 0 1 0 0 1 0 0 1 0
0911 1 0 0 0 0 0 0 0 1 0
0912 1 0 0 0 1 0 0 0 0 0
Spectrographic analysis (ppm)
Sample
received
Ti
Titanium
Si
Silicon
Na
Sodium
K
Potassium
B
Boron
Mg
Magnesium
Ca
Calcium
Ba
Barium
P
Phosphorus
Zn
Zinc
0829 5 0 1 4 0 0 0 0 327 505
0830 0 0 2 4 0 0 0 0 305 482
0911 0 0 1 2 0 0 0 0 359 482
0912 0 2 0 1 0 0 0 0 385 482
Physical properties
Sample
received
%
Fuel
%
Soot
%
Water
Viscocity
40 °C
Viscocity
100 °C
TAN TBN
0829 < 0.1 31.6 0.35
0830 < 0.1 31.0 0.38
0911 < 0.1 31.0 0.04
0912 < 0.1 31.0 0.08
Physical properties
Sample
received
Count
ISO #
PC/mL
> 5 µm
PC/mL
> 10 µm
PC/mL
> 15 µm
PC/mL
> 20 µm
PC/mL
> 30 µm
PC/mL
> 40 µm
0829 18/11 340 62 16 7 1 0
0830 15/12 214 60 23 12 3 1
0911 14/08 100 12 2 1 0 0
0912 12/08 33 10 3 1 1 0
Physical properties
Sample
received
IR
Water
IR
Hydrocarbons
IR
Oxidation
IR
Nitration
IR
Glycol
0829 1 717 1 0 1
0830 1 711 0 0 1
0911 0 733 1 0 1
0912 1 841 0 0 1
System 2
Sample 0829 was taken upstream before the installation of Halex Coils.
Sample 0830 was taken downstream before the installation of Halex Coils.
Sample 0911 was taken upstream after the installation of Halex Coils.
Sample 0912 was taken downstream after the installation of Halex Coils.
Spectrographic analysis (ppm)
Sample
received
Fe
Iron
Cr
Chromium
Mo
Molybdenum
Al
Aluminum
Cu
Copper
Pb
Lead
Sn
Tin
Ag
Silver
Ni
Nickel
Sb
Antimony
0829 0 0 1 0 1 0 1 0 2 0
0830 0 0 0 0 1 1 0 0 2 0
0911 0 0 0 0 1 0 0 0 1 0
0912 0 0 0 0 1 0 0 0 0 0
Spectrographic analysis (ppm)
Sample
received
Ti
Titanium
Si
Silicon
Na
Sodium
K
Potassium
B
Boron
Mg
Magnesium
Ca
Calcium
Ba
Barium
P
Phosphorus
Zn
Zinc
0829 0 0 1 4 0 0 0 0 314 544
0830 2 1 1 3 0 0 0 0 353 488
0911 0 2 0 2 0 0 53 0 371 475
0912 0 1 0 1 0 0 50 0 387 404
Physical properties
Sample
received
%
Fuel
%
Soot
%
Water
Viscocity
40 °C
Viscocity
100 °C
TAN TBN
0829 < 0.1 31.4 0.33
0830 < 0.1 31.0 0.33
0911 < 0.1 32.0 0.17
0912 < 0.1 31.4 0.18
Physical properties
Sample
received
Count
ISO #
PC/mL
> 5 µm
PC/mL
> 10 µm
PC/mL
> 15 µm
PC/mL
> 20 µm
PC/mL
> 30 µm
PC/mL
> 40 µm
0829 20/10 15658 8713 1832 344 21 5
0830 16/14 387 174 112 81 4 1
0911 13/10 55 18 7 3 2 1
0912 11/08 15 6 2 1 0 0
Physical properties
Sample
received
IR
Water
IR
Hydrocarbons
IR
Oxidation
IR
Nitration
IR
Glycol
0829 1 685 2 1 1
0830 1 710 2 0 1
0911 1 780 4 2 1
0912 1 781 1 0 0